batt: Improve discharge curve values
Values calculated using multiple tests on 3 PineTimes
This commit is contained in:
parent
762d52e114
commit
8b0d888952
|
@ -61,14 +61,8 @@ void Battery::SaadcInit() {
|
|||
}
|
||||
|
||||
void Battery::SaadcEventHandler(nrfx_saadc_evt_t const* p_event) {
|
||||
static const Utility::LinearApproximation<uint16_t, uint8_t, 6> aprox {{{
|
||||
{3500, 0}, // Minimum voltage before shutdown (depends on the battery)
|
||||
{3600, 10}, // Keen point that corresponds to 10%
|
||||
{3700, 25},
|
||||
{3750, 50},
|
||||
{3900, 75},
|
||||
{4180, 100} // Maximum voltage during charging is 4.21V
|
||||
}}};
|
||||
static const Utility::LinearApproximation<uint16_t, uint8_t, 6> approx {
|
||||
{{{3500, 0}, {3616, 3}, {3723, 22}, {3776, 48}, {3979, 79}, {4180, 100}}}};
|
||||
|
||||
if (p_event->type == NRFX_SAADC_EVT_DONE) {
|
||||
|
||||
|
@ -83,7 +77,8 @@ void Battery::SaadcEventHandler(nrfx_saadc_evt_t const* p_event) {
|
|||
|
||||
uint8_t newPercent = 100;
|
||||
if (!isFull) {
|
||||
newPercent = std::min(aprox.GetValue(voltage), isCharging ? uint8_t {99} : uint8_t {100});
|
||||
// max. voltage while charging is higher than when discharging
|
||||
newPercent = std::min(approx.GetValue(voltage), isCharging ? uint8_t {99} : uint8_t {100});
|
||||
}
|
||||
|
||||
if (isPowerPresent) {
|
||||
|
|
Loading…
Reference in a new issue